Dark Matter Search Results from <math display="inline"><mrow><mn>1.54</mn><mtext> </mtext><mtext> </mtext><mi>Tonne</mi><mo>·</mo><mi>Year</mi></mrow></math> Exposure of PandaX-4T
INSPIRE: 2813747
arXiv: 2408.00664
DOI: 10.1103/PhysRevLett.134.011805
Authors: Bo, Zihao, Chen, Wei, Chen, Xun, Chen, Yunhua, Cheng, Zhaokan, Cui, Xiangyi, Fan, Yingjie, Fang, Deqing, Gao, Zhixing, Geng, Lisheng, Giboni, Karl, Guo, Xunan, Guo, Xuyuan, Guo, Zichao, Han, Chencheng, Han, Ke, He, Changda, He, Jinrong, Huang, Di, Huang, Houqi, Huang, Junting, Hou, Ruquan, Hou, Yu, Ji, Xiangdong, Ji, Xiangpan, Ju, Yonglin, Li, Chenxiang, Li, Jiafu, Li, Mingchuan, Li, Shuaijie, Li, Tao, Li, Zhiyuan, Lin, Qing, Liu, Jianglai, Lu, Congcong, Lu, Xiaoying, Luo, Lingyin, Luo, Yunyang, Ma, Wenbo, Ma, Yugang, Mao, Yajun, Meng, Yue, Ning, Xuyang, Pang, Binyu, Qi, Ningchun, Qian, Zhicheng, Ren, Xiangxiang, Shan, Dong, Shang, Xiaofeng, Shao, Xiyuan, Shen, Guofang, Shen, Manbin, Sun, Wenliang, Tao, Yi, Wang, Anqing, Wang, Guanbo, Wang, Hao, Wang, Jiamin, Wang, Lei, Wang, Meng, Wang, Qiuhong, Wang, Shaobo, Wang, Siguang, Wang, Wei, Wang, Xiuli, Wang, Xu, Wang, Zhou, Wei, Yuehuan, Wu, Weihao, Wu, Yuan, Xiao, Mengjiao, Xiao, Xiang, Xiong, Kaizhi, Xu, Yifan, Yao, Shunyu, Yan, Binbin, Yan, Xiyu, Yang, Yong, Ye, Peihua, Yu, Chunxu, Yuan, Ying, Yuan, Zhe, Yun, Youhui, Zeng, Xinning, Zhang, Minzhen, Zhang, Peng, Zhang, Shibo, Zhang, Shu, Zhang, Tao, Zhang, Wei, Zhang, Yang, Zhang, Yingxin, Zhang, Yuanyuan, Zhao, Li, Zhou, Jifang, Zhou, Jiaxu, Zhou, Jiayi, Zhou, Ning, Zhou, Xiaopeng, Zhou, Yubo, Zhou, Zhizhen
Submitted: 1 August 2024
Subjects:
- hep-ex
- Experiment-HEP
Journal reference: Phys.Rev.Lett. 134 (1) 011805 (2025)
Citations: 192
Abstract
In this Letter, we report the dark matter search results from the commissioning run (Run0) and the first science run (Run1) of the PandaX-4T experiment. The two datasets were processed with a unified procedure, with the Run1 data treated blindly. The data processing is improved compared to previous work, unifying the low-level signal reconstruction in a wide energy range up to 120 keV. With a total exposure of <math display="inline"><mrow><mn>1.54</mn><mtext> </mtext><mtext> </mtext><mi>tonne</mi><mo>·</mo><mi>year</mi></mrow></math>, no significant excess of nuclear recoil events is found. The lowest 90% confidence level exclusion on the spin-independent cross section is <math display="inline"><mrow><mn>1.6</mn><mo>×</mo><msup><mrow><mn>10</mn></mrow><mrow><mo>-</mo><mn>47</mn></mrow></msup><mtext> </mtext><mtext> </mtext><msup><mrow><mi>cm</mi></mrow><mrow><mn>2</mn></mrow></msup></mrow></math> at a dark matter mass of <math display="inline"><mn>40</mn><mtext> </mtext><mtext> </mtext><mi>GeV</mi><mo>/</mo><msup><mi>c</mi><mn>2</mn></msup></math>. Our results represent the most stringent constraint for a dark matter mass above <math display="inline"><mrow><mn>100</mn><mtext> </mtext><mtext> </mtext><mi>GeV</mi><mo>/</mo><msup><mrow><mi>c</mi></mrow><mrow><mn>2</mn></mrow></msup></mrow></math>.