Measurement of high-pressure xenon gas absorption in acrylic
INSPIRE: 2039394
arXiv: 2202.13989
DOI: 10.1088/1748-0221/17/05/P05027
Authors: Lin, Heng, Ni, Kaixiang, Du, Haiyan, Han, Ke, Ji, Xiangdong, Li, Tao, Luo, Lingyin, Wang, Shaobo, Yan, Xiyv, Zeng, Xinning, Zhang, Wenming
Submitted: 28 February 2022
Subjects:
- physics.ins-det
- hep-ex
- Instrumentation
- Experiment-HEP
Journal reference: JINST 17 (05) P05027 (2022)
Citations: 2
Abstract
Acrylic is a popular structural material in experiments requiring low background because of its radio-purity, machinability, and mechanical strength. However, its porosity may cause significant gas absorption and influence the detector stability in the long term. The interaction between acrylic and other detector materials becomes one of the key concerns in the detector design. In this paper, we carry out an experiment to measure quantitatively the absorption process of high-pressure xenon gas into acrylic. A specific setup is designed for the measurement, and systematic measurements are done to obtain a result of the absorption amount: 0.98 g xenon into 332 g of acrylic.