{
  "uuid": "7cde0efc-69a2-4dea-9256-b606dabe1b4e",
  "links": {
    "bibtex": "https://inspirehep.net/api/literature/1762072?format=bibtex",
    "latex-eu": "https://inspirehep.net/api/literature/1762072?format=latex-eu",
    "latex-us": "https://inspirehep.net/api/literature/1762072?format=latex-us",
    "json": "https://inspirehep.net/api/literature/1762072?format=json",
    "json-expanded": "https://inspirehep.net/api/literature/1762072?format=json-expanded",
    "cv": "https://inspirehep.net/api/literature/1762072?format=cv",
    "citations": "https://inspirehep.net/api/literature/?q=refersto%3Arecid%3A1762072"
  },
  "id": "1762072",
  "revision_id": 105,
  "metadata": {
    "citation_count": 19,
    "publication_info": [
      {
        "year": 2020,
        "artid": "93",
        "page_start": "93",
        "journal_issue": "9",
        "journal_title": "Nucl.Sci.Tech.",
        "journal_record": {
          "$ref": "https://inspirehep.net/api/journals/1212635"
        },
        "journal_volume": "31"
      }
    ],
    "citation_count_without_self_citations": 12,
    "core": true,
    "dois": [
      {
        "value": "10.1007/s41365-020-00797-4",
        "source": "bibmatch"
      }
    ],
    "titles": [
      {
        "title": "On proportional scintillation in very large liquid xenon detectors",
        "source": "Springer"
      },
      {
        "title": "On Proportional Scintillation in Very Large LXe Detectors",
        "source": "arXiv"
      }
    ],
    "$schema": "https://inspirehep.net/schemas/records/hep.json",
    "authors": [
      {
        "ids": [
          {
            "value": "0000-0001-6577-4419",
            "schema": "ORCID"
          }
        ],
        "uuid": "adcd35de-024b-4d82-b008-c1bc2d7fb72c",
        "emails": [
          "pratibhajuyal@sjtu.edu.cn"
        ],
        "record": {
          "$ref": "https://inspirehep.net/api/authors/1886688"
        },
        "full_name": "Juyal, Pratibha",
        "affiliations": [
          {
            "value": "Shanghai Jiao Tong U.",
            "record": {
              "$ref": "https://inspirehep.net/api/institutions/911458"
            }
          }
        ],
        "signature_block": "JYALp",
        "raw_affiliations": [
          {
            "value": "School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai Key Laboratory for Particle Physics and Cosmology(INPAC), 800 Dongchuan Road, 200240 Shanghai, China"
          }
        ],
        "affiliations_identifiers": [
          {
            "value": "grid.16821.3c",
            "schema": "GRID"
          }
        ]
      },
      {
        "uuid": "6613c57e-aebb-4337-9857-f94337d2d53e",
        "record": {
          "$ref": "https://inspirehep.net/api/authors/1022852"
        },
        "full_name": "Giboni, Karl-Ludwig",
        "affiliations": [
          {
            "value": "Shanghai Jiao Tong U.",
            "record": {
              "$ref": "https://inspirehep.net/api/institutions/911458"
            }
          }
        ],
        "signature_block": "GABANk",
        "raw_affiliations": [
          {
            "value": "School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai Key Laboratory for Particle Physics and Cosmology(INPAC), 800 Dongchuan Road, 200240 Shanghai, China"
          }
        ],
        "affiliations_identifiers": [
          {
            "value": "grid.16821.3c",
            "schema": "GRID"
          }
        ]
      },
      {
        "uuid": "11708e63-928e-402c-9e85-a408d8474451",
        "record": {
          "$ref": "https://inspirehep.net/api/authors/1004347"
        },
        "full_name": "Ji, Xiang-Dong",
        "affiliations": [
          {
            "value": "Shanghai Jiao Tong U.",
            "record": {
              "$ref": "https://inspirehep.net/api/institutions/911458"
            }
          }
        ],
        "signature_block": "Jx",
        "raw_affiliations": [
          {
            "value": "School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai Key Laboratory for Particle Physics and Cosmology(INPAC), 800 Dongchuan Road, 200240 Shanghai, China"
          }
        ],
        "affiliations_identifiers": [
          {
            "value": "grid.16821.3c",
            "schema": "GRID"
          }
        ]
      },
      {
        "uuid": "12d475c6-9868-4ee5-9b0a-e31a358331d7",
        "record": {
          "$ref": "https://inspirehep.net/api/authors/2133274"
        },
        "full_name": "Liu, Jian-Lai",
        "affiliations": [
          {
            "value": "Shanghai Jiao Tong U.",
            "record": {
              "$ref": "https://inspirehep.net/api/institutions/911458"
            }
          }
        ],
        "signature_block": "Lj",
        "raw_affiliations": [
          {
            "value": "School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai Key Laboratory for Particle Physics and Cosmology(INPAC), 800 Dongchuan Road, 200240 Shanghai, China"
          }
        ],
        "affiliations_identifiers": [
          {
            "value": "grid.16821.3c",
            "schema": "GRID"
          }
        ]
      }
    ],
    "curated": true,
    "figures": [
      {
        "key": "5e8eaff90636809ffd437e617500cb5a",
        "url": "https://inspirehep.net/files/5e8eaff90636809ffd437e617500cb5a",
        "source": "arxiv",
        "caption": "Field lines around the anode region for a single phase detector",
        "filename": "fig4.png"
      },
      {
        "key": "50ad2128604f608b21d042211d91ad1d",
        "url": "https://inspirehep.net/files/50ad2128604f608b21d042211d91ad1d",
        "source": "arxiv",
        "caption": "Drift paths of ionization electrons from a point source to the anode wire in the CAL experiment. (reproduced from ref. I with permission of the authors). a. On the left, the original plot. i.e. the case of a single anode wire. The three different flight paths can be identified. b. On the right, the case with three anode wires. The plot was not redrawn, but modified by symmetry arguments. All the flight paths are now the same, but the two additional components are ending on the adjacent anode wires.",
        "filename": "fig2.png"
      },
      {
        "key": "49a88eae7e22592b20446988dcbffe52",
        "url": "https://inspirehep.net/files/49a88eae7e22592b20446988dcbffe52",
        "source": "arxiv",
        "caption": "Light Observed on the bottom and top PMT from proportional scintillation in liquid xenon with a 10 $\\mu$m wire in dependence of the distance from the wire. Note that the light is only produced very close to the wire(less than 5 $\\mu$m away).",
        "filename": "fig3.png"
      },
      {
        "key": "a1a4cbd07edd823bccebe6a87864d540",
        "url": "https://inspirehep.net/files/a1a4cbd07edd823bccebe6a87864d540",
        "source": "arxiv",
        "caption": "Schematic working principle of a dual phase (left) and a single phase (right) LXe detector. The differences are mainly the position of the liquid level and the diameter of the anode wires.",
        "filename": "fig1.png"
      }
    ],
    "license": [
      {
        "url": "http://arxiv.org/licenses/nonexclusive-distrib/1.0/",
        "license": "arXiv nonexclusive-distrib 1.0",
        "material": "preprint"
      }
    ],
    "texkeys": [
      "Juyal:2019gch"
    ],
    "citeable": true,
    "imprints": [
      {
        "date": "2020-09-01"
      }
    ],
    "keywords": [
      {
        "value": "Liquid Detectors",
        "source": "author"
      },
      {
        "value": "Time projection Chambers (TPC)",
        "source": "author"
      },
      {
        "value": "Charge transport",
        "source": "author"
      },
      {
        "value": "multiplication and electroluminescence in rare gases and liquids",
        "source": "author"
      },
      {
        "value": "Liquid detectors",
        "source": "author"
      },
      {
        "value": "Time projection chambers (TPC)",
        "source": "author"
      },
      {
        "value": "Multiplication and electroluminescence in rare gases and liquids",
        "source": "author"
      },
      {
        "value": "experimental equipment",
        "schema": "INSPIRE"
      },
      {
        "value": "dark matter: detector",
        "schema": "INSPIRE"
      },
      {
        "value": "liquid",
        "schema": "INSPIRE"
      },
      {
        "value": "xenon",
        "schema": "INSPIRE"
      },
      {
        "value": "time projection chamber",
        "schema": "INSPIRE"
      },
      {
        "value": "shadowing",
        "schema": "INSPIRE"
      },
      {
        "value": "geometry",
        "schema": "INSPIRE"
      },
      {
        "value": "electron",
        "schema": "INSPIRE"
      },
      {
        "value": "wire",
        "schema": "INSPIRE"
      }
    ],
    "refereed": true,
    "abstracts": [
      {
        "value": "The charge readout of a liquid xenon (LXe) detector via proportional scintillation in the liquid phase was first realized by the Waseda group 40 years ago, but the technical challenges involved were overwhelming. Although the tests were successful, this method was finally discarded and eventually nearly forgotten. Currently, this approach is not considered for large LXe dark matter detectors. Instead, the dual-phase technology was selected despite many limitations and challenges. In two independent studies, two groups from Columbia University and Shanghai Jiao Tong University reevaluated proportional scintillation in the liquid phase. Both studies established the merits for very large LXe detectors, but the Columbia group also encountered apparent limitations, namely the shadowing of the light by the anode wires, and a dependence of the pulse shape on the drift path of the electrons in the anode region. The differences between the two studies, however, are not intrinsic to the technique, but a direct consequence of the chosen geometry. Taking the geometrical differences into account, the results match without ambiguity. They also agree with the original results from the Waseda group.",
        "source": "Springer"
      },
      {
        "value": "The charge read out of a LXe detector via Proportional Scintillation in the liquid phase was first realized by the Waseda group 40 years ago, but at that time the technical challenges were overwhelming. Although the tests were successful, this method was finally discarded and eventually nearly forgotten. For present day large LXe Dark Matter detectors, this approach was not even considered. Instead the Dual Phase technology was selected despite many limitations and challenges. In two independent studies the groups from Columbia University and Shanghai Jiao Tong University reevaluated Proportional Scintillation in the liquid phase. Both established the merits for very large LXe detectors, but the Columbia group also encountered apparent limitations, namely the shadowing of the light by the anode wires and a dependence of the pulse shape on the drift path of the electrons in the anode region. The discrepancies between the two studies, however, are not intrinsic to the technique, but a direct consequence of the chosen geometry. Taking the geometrical differences into account the results match without ambiguity. They also agree with the original results from the Waseda group. With the technical problems solved, the path is now open to use this method in future large LXe TPCs.",
        "source": "arXiv"
      }
    ],
    "references": [
      {
        "raw_refs": [
          {
            "value": "[1] MI Lopes, V Chepel, WF Schmidt, E Illenberger: Rare gas liquid detectors, pages 331-388 in: MI Lopes, V Chepel, WF Schmidt, E Illenberger: Electronic Excitations in Liquefied Rare Gases, American Scientific Publishers, Valencia, 2005",
            "schema": "text"
          }
        ],
        "reference": {
          "misc": [
            "Chepel, WF Schmidt, E",
            "Illenberger: Rare gas liquid detectors, pages 331-388 in: MI Lopes, V",
            "Illenberger: Electronic Excitations in Liquefied Rare Gases, American Scientific Publishers, Valencia"
          ],
          "label": "1",
          "authors": [
            {
              "full_name": "MI Lopes, V."
            }
          ],
          "publication_info": {
            "year": 2005
          }
        }
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/1379873"
        },
        "raw_refs": [
          {
            "value": "[2] E. Aprile, A.E. Bolotnikov, A.I. Bolozdynya et al., Noble Gas Detectors (Wiley, Weinheim, 2006). 10.1002/9783527610020",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1002/9783527610020"
          ],
          "misc": [
            "Noble Gas Detectors",
            "Weinheim,)"
          ],
          "label": "2",
          "authors": [
            {
              "full_name": "Aprile, E."
            },
            {
              "full_name": "Bolotnikov, A.E."
            },
            {
              "full_name": "Bolozdynya, A.I."
            }
          ],
          "publication_info": {
            "year": 2006
          }
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/835190"
        },
        "raw_refs": [
          {
            "value": "[3] E Aprile, T Doke: Liquid Xenon detectors for particle physics and astrophysics, ['Rev.Mod.Phys.,82,2053'], DOI: 10.1103/revmodphys.82.2053",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1103/revmodphys.82.2053"
          ],
          "label": "3"
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/1210572"
        },
        "raw_refs": [
          {
            "value": "[4] K Abe, K Hieda, K Hiraide: XMASS detector, ['Nucl.Instrum.Meth.,A716,78'], DOI: 10.1016/j.nima.2013.03.059",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1016/j.nima.2013.03.059"
          ],
          "label": "4"
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/842987"
        },
        "raw_refs": [
          {
            "value": "[5] E. Aprile, J. Angle, F. Arneodo et al., (XENON10 collaboration), Design and performance of the XENON10 dark matter experiment. Astropart. Phys. 34 , 679 (2011). 10.1016/j.astropartphys.2011.01.006",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1016/j.astropartphys.2011.01.006"
          ],
          "misc": [
            "(XENON10 collaboration), Design and performance of the XENON10 dark matter experiment"
          ],
          "label": "5",
          "authors": [
            {
              "full_name": "Aprile, E."
            },
            {
              "full_name": "Angle, J."
            },
            {
              "full_name": "Arneodo, F."
            }
          ],
          "publication_info": {
            "year": 2011,
            "artid": "679",
            "page_start": "679",
            "journal_title": "Astropart.Phys.",
            "journal_volume": "34"
          }
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/1121844"
        },
        "raw_refs": [
          {
            "value": "[6] V Chepel, H Arajo: Liquid noble gas detectors for low energy particle physics, ['JINST,8,R04001'], DOI: 10.1088/1748-0221/8/04/r04001",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1088/1748-0221/8/04/r04001"
          ],
          "label": "6"
        },
        "curated_relation": false
      },
      {
        "raw_refs": [
          {
            "value": "[7] BA Dolgoshein: New method of registration of ionizing particle tracks in condensed matter, ['JETP Lett.,11,351']",
            "schema": "text"
          }
        ],
        "reference": {
          "misc": [
            "BA Dolgoshein: New method of registration of ionizing particle tracks in condensed matter, ['"
          ],
          "label": "7",
          "publication_info": {
            "artid": "351",
            "page_start": "351",
            "journal_title": "JETP Lett.",
            "journal_volume": "11"
          }
        }
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/145392"
        },
        "raw_refs": [
          {
            "value": "[8] M Miyajima, Y Hoshi, T Doke: A self-triggered liquid xenon drift chamber by the use of proportional ionization or proportional scintillation, ['Nucl.Instrum.Meth.,160,239'], DOI: 10.1016/0029-554x(79)90599-8",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1016/0029-554x(79)90599-8"
          ],
          "label": "8"
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/145391"
        },
        "raw_refs": [
          {
            "value": "[9] K Masuda, S Takasu, T Doke: A liquid xenon proportional scintillation counter, ['Nucl.Instrum.Meth.,160,247'], DOI: 10.1016/0029-554x(79)90600-1",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1016/0029-554x(79)90600-1"
          ],
          "label": "9"
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/1312410"
        },
        "raw_refs": [
          {
            "value": "[10] E Aprile, H Contreras, LW Goetzke: Measurements of proportional scintillation and electron multiplication in liquid xenon using thin wires, ['JINST,9,P11012'], DOI: 10.1088/1748-0221/9/11/p11012",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1088/1748-0221/9/11/p11012"
          ],
          "label": "10"
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/1333910"
        },
        "raw_refs": [
          {
            "value": "[11] T Ye, KL Giboni, X Ji: Initial evaluation of proportional scintillation in liquid xenon for direct dark matter detection, ['JINST,9,P12007'], DOI: 10.1088/1748-0221/9/12/p12007",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1088/1748-0221/9/12/p12007"
          ],
          "label": "11"
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/1471703"
        },
        "raw_refs": [
          {
            "value": "[12] J Aalbers, F Agostini, M Alfonsi: Darwin: towards the ultimate dark matter detector, ['JCAP,1611,017'], DOI: 10.1088/1475-7516/2016/11/017",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1088/1475-7516/2016/11/017"
          ],
          "label": "12"
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/1263348"
        },
        "raw_refs": [
          {
            "value": "[13] E Aprile, M Alfonsi, K Arisaka: Observation and applications of single-electron charge signals in the XENON100 experiment, ['J.Phys.,G41,035201'], DOI: 10.1088/0954-3899/41/3/035201",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1088/0954-3899/41/3/035201"
          ],
          "label": "13"
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/1663506"
        },
        "raw_refs": [
          {
            "value": "[14] J Hogenbirk, P Aalbers, A Breur: Precision measurements of the scintillation pulse shape for low-energy recoils in liquid xenon, ['JINST,13,P05016'], DOI: 10.1088/1748-0221/13/05/p05016",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1088/1748-0221/13/05/p05016"
          ],
          "label": "14"
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/1123760"
        },
        "raw_refs": [
          {
            "value": "[15] E. Aprile, M. Alfonsi, K. Arisaka et al., (XENON100 Collaboration), Dark matter results from 225 live days of XENON100 data. Phys. Rev. Lett. 109 , 181301 (2012). 10.1103/physrevlett.109.181301",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1103/physrevlett.109.181301"
          ],
          "misc": [
            "(XENON100 Collaboration), Dark matter results from 225 live days of XENON100 data"
          ],
          "label": "15",
          "authors": [
            {
              "full_name": "Aprile, E."
            },
            {
              "full_name": "Alfonsi, M."
            },
            {
              "full_name": "Arisaka, K."
            }
          ],
          "publication_info": {
            "year": 2012,
            "artid": "181301",
            "journal_title": "Phys.Rev.Lett.",
            "journal_volume": "109"
          }
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/1477816"
        },
        "raw_refs": [
          {
            "value": "[16] Andi Tan M. Xiao, X. Cui et al., (PandaX collaboration), Dark matter results from first 98.7 days of data from the panda X-II experiment. Phys. Rev. Lett. 117 (2016) 121303. 10.1103/physrevlett.117.121303",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1103/physrevlett.117.121303"
          ],
          "misc": [
            "Andi",
            "(PandaX collaboration), Dark matter results from first 98.7 days of data from the panda X-II",
            "experiment"
          ],
          "label": "16",
          "authors": [
            {
              "full_name": "Xiao, Tan M."
            },
            {
              "full_name": "Cui, X."
            }
          ],
          "publication_info": {
            "year": 2016,
            "artid": "121303",
            "journal_title": "Phys.Rev.Lett.",
            "journal_volume": "117"
          }
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/1420704"
        },
        "raw_refs": [
          {
            "value": "[17] D.S. Akerib, H.M. Arajo, X. Bai et al., (LUX collaboration), Results on the spin-dependent scattering of weakly interacting massive particles on nucleons from the run 3 data of the LUX experiment. Phys. Rev. Lett. 116 , 161302 (2016). 10.1103/physrevlett.116.161302",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1103/physrevlett.116.161302"
          ],
          "misc": [
            "(LUX collaboration), Results on the spin-dependent scattering of weakly interacting massive particles on nucleons from the run 3 data of the LUX experiment"
          ],
          "label": "17",
          "authors": [
            {
              "full_name": "Akerib, D.S."
            },
            {
              "full_name": "Arajo, H.M."
            },
            {
              "full_name": "Bai, X."
            }
          ],
          "publication_info": {
            "year": 2016,
            "artid": "161302",
            "journal_title": "Phys.Rev.Lett.",
            "journal_volume": "116"
          }
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/1722510"
        },
        "raw_refs": [
          {
            "value": "[18] E. Aprile, J. Aalbers, F. Agostini et al., (XENON1T collaboration), XENON1T dark matter data analysis: signal and background models and statistical inference. Phys. Rev. Lett. 99 , 112009 (2019). 10.1103/physrevd.99.112009",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1103/physrevd.99.112009"
          ],
          "misc": [
            "(XENON1T collaboration), XENON1T dark matter data analysis: signal and background models and statistical inference"
          ],
          "label": "18",
          "authors": [
            {
              "full_name": "Aprile, E."
            },
            {
              "full_name": "Aalbers, J."
            },
            {
              "full_name": "Agostini, F."
            }
          ],
          "publication_info": {
            "year": 2019,
            "artid": "112009",
            "journal_title": "Phys.Rev.Lett.",
            "journal_volume": "99"
          }
        },
        "curated_relation": false
      },
      {
        "raw_refs": [
          {
            "value": "[19] O Bunemann, TE Cranshaw, JA Harvey: Design of grid ionization chambers, Can. J. Res. 27 (1949) 191, DOI: 10.1139/cjr49a-019",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1139/cjr49a-019"
          ],
          "label": "19"
        }
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/1377719"
        },
        "raw_refs": [
          {
            "value": "[20] E Gatti, G Padovini, L Quartapelle: Considerations for the design of a time projection liquid argon ionization chamber, IEEE NS 26, No. 2 (1979) 2910, DOI: 10.1109/tns.1979.4330558",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1109/tns.1979.4330558"
          ],
          "label": "20"
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/1295693"
        },
        "raw_refs": [
          {
            "value": "[21] X Cao, X Chen, Y Chen: PandaX: a liquid xenon dark matter experiment at CJPL, Sci. China Phys. Mech. Astron. (2014) , DOI: 10.1007/s11433-014-5521-2",
            "schema": "text"
          }
        ],
        "reference": {
          "dois": [
            "10.1007/s11433-014-5521-2"
          ],
          "label": "21"
        },
        "curated_relation": false
      }
    ],
    "arxiv_eprints": [
      {
        "value": "1910.13160",
        "categories": [
          "physics.ins-det"
        ]
      }
    ],
    "document_type": [
      "article"
    ],
    "preprint_date": "2019-10-29",
    "control_number": 1762072,
    "legacy_version": "20201030075039.0",
    "number_of_pages": 12,
    "inspire_categories": [
      {
        "term": "Instrumentation",
        "source": "arxiv"
      },
      {
        "term": "Instrumentation"
      }
    ],
    "legacy_creation_date": "2019-10-30"
  },
  "updated": "2023-03-07T02:41:31.777825+00:00",
  "created": "2019-10-30T00:00:00+00:00"
}