# Update of the trigger system of the PandaX\-II experiment

**INSPIRE:** [1609068](https://inspirehep.net/literature/1609068)
**arXiv:** [1707\.02134](https://arxiv.org/abs/1707.02134)
**DOI:** [10\.1088/1748\-0221/12/08/T08004](https://doi.org/10.1088/1748-0221/12/08/T08004)

**Authors:** Wu, Qinyu, Chen, Xun, Ji, Xiangdong, Liu, Jianglai, Lei, Siao, Xiangxiang Ren, Wang, Meng, Xiao, Mengjiao, Xie, Pengwei, Yan, Binbin, Yang, Yong

**Submitted:** 7 July 2017

**Subjects:**
- physics\.ins\-det
- hep\-ex
- Instrumentation
- Experiment\-HEP

**Journal reference:** JINST 12 \(08\) T08004 \(2017\)

**Citations:** 9

## Abstract

PandaX\-II experiment is a dark matter direct detection experiment using about half\-ton of liquid xenon as the sensitive target\. The electrical pulses detected by photomultiplier tubes from scintillation photons of xenon are recorded by waveform digitizers\. The data acquisition of PandaX\-II relies on a trigger system that generates common trigger signals for all waveform digitizers\. Previously an analog device\-based trigger system was used for the data acquisition system\. In this paper we present a new FPGA\-based trigger system\. The design of this system and trigger algorithms are described\. The performance of this system on real data is presented\.