The Electronics and Data Acquisition System for the PandaX-I Dark Matter Experiment
INSPIRE: 1419066
arXiv: 1602.00858
DOI: 10.1088/1748-0221/11/04/T04002
Authors: Ren, Xiangxiang, Chen, Xun, Ji, Xiangdong, Li, Shaoli, Lei, Siao, Liu, Jianglai, Wang, Meng, Xiao, Mengjiao, Xie, Pengwei, Yan, Binbin
Submitted: 2 February 2016
Subjects:
- physics.ins-det
- hep-ex
- Instrumentation
- Experiment-HEP
Journal reference: JINST 11 (04) T04002 (2016)
Citations: 5
Abstract
We describe the electronics and data acquisition system used in the first phase of the PandaX experiment—a 120 kg dual-phase liquid xenon dark matter direct detection experiment in the China Jin-Ping Underground Laboratory. This system utilized 180 channels of commercial flash ADC waveform digitizers. During the entire experimental run, the system has achieved low trigger threshold (<1 keV electron-equivalent energy) and low deadtime data acquisition.