{
  "revision_id": 94,
  "created": "2012-07-23T00:00:00+00:00",
  "links": {
    "bibtex": "https://inspirehep.net/api/literature/1123430?format=bibtex",
    "latex-eu": "https://inspirehep.net/api/literature/1123430?format=latex-eu",
    "latex-us": "https://inspirehep.net/api/literature/1123430?format=latex-us",
    "json": "https://inspirehep.net/api/literature/1123430?format=json",
    "json-expanded": "https://inspirehep.net/api/literature/1123430?format=json-expanded",
    "cv": "https://inspirehep.net/api/literature/1123430?format=cv",
    "citations": "https://inspirehep.net/api/literature/?q=refersto%3Arecid%3A1123430"
  },
  "id": "1123430",
  "uuid": "634cb166-08c5-430a-92f1-2ccd64dff9e0",
  "metadata": {
    "citation_count_without_self_citations": 21,
    "publication_info": [
      {
        "year": 2013,
        "artid": "P01002",
        "journal_title": "JINST",
        "journal_record": {
          "$ref": "https://inspirehep.net/api/journals/1212215"
        },
        "journal_volume": "8"
      }
    ],
    "citation_count": 28,
    "core": true,
    "dois": [
      {
        "value": "10.1088/1748-0221/8/01/P01002"
      }
    ],
    "titles": [
      {
        "title": "The Cryogenic System for the Panda-X Dark Matter Search Experiment"
      },
      {
        "title": "The Cryogenic System for the Panda-X Dark Matter Search Experiment",
        "source": "arXiv"
      }
    ],
    "$schema": "https://inspirehep.net/schemas/records/hep.json",
    "authors": [
      {
        "uuid": "b15fc7e7-fe2e-4112-9ff9-bf3a2833e421",
        "record": {
          "$ref": "https://inspirehep.net/api/authors/1048075"
        },
        "full_name": "Gong, H.",
        "affiliations": [
          {
            "value": "Shanghai Jiaotong U.",
            "record": {
              "$ref": "https://inspirehep.net/api/institutions/904740"
            }
          }
        ],
        "signature_block": "GANGh"
      },
      {
        "uuid": "455a7933-0c1d-4a8b-98e5-d1fe904834e8",
        "record": {
          "$ref": "https://inspirehep.net/api/authors/1022852"
        },
        "full_name": "Giboni, K.L.",
        "affiliations": [
          {
            "value": "Shanghai Jiaotong U.",
            "record": {
              "$ref": "https://inspirehep.net/api/institutions/904740"
            }
          }
        ],
        "signature_block": "GABANk"
      },
      {
        "uuid": "8e90cf0c-7e78-418c-ac16-cd88d68c20c9",
        "record": {
          "$ref": "https://inspirehep.net/api/authors/1004347"
        },
        "full_name": "Ji, X.",
        "affiliations": [
          {
            "value": "Shanghai Jiaotong U.",
            "record": {
              "$ref": "https://inspirehep.net/api/institutions/904740"
            }
          },
          {
            "value": "Maryland U.",
            "record": {
              "$ref": "https://inspirehep.net/api/institutions/902990"
            }
          }
        ],
        "signature_block": "Jx",
        "curated_relation": true
      },
      {
        "uuid": "03019f48-c870-4042-a510-48fdf73ffa23",
        "record": {
          "$ref": "https://inspirehep.net/api/authors/2239672"
        },
        "full_name": "Tan, A.",
        "affiliations": [
          {
            "value": "Shanghai Jiaotong U.",
            "record": {
              "$ref": "https://inspirehep.net/api/institutions/904740"
            }
          },
          {
            "value": "Maryland U.",
            "record": {
              "$ref": "https://inspirehep.net/api/institutions/902990"
            }
          }
        ],
        "signature_block": "TANa"
      },
      {
        "uuid": "dc106a35-33cd-4ea3-92cc-9ff29f76de7a",
        "record": {
          "$ref": "https://inspirehep.net/api/authors/1984125"
        },
        "full_name": "Zhao, L.",
        "affiliations": [
          {
            "value": "Shanghai Jiaotong U.",
            "record": {
              "$ref": "https://inspirehep.net/api/institutions/904740"
            }
          }
        ],
        "signature_block": "Zl"
      }
    ],
    "curated": true,
    "license": [
      {
        "url": "http://arxiv.org/licenses/nonexclusive-distrib/1.0/",
        "imposing": "arXiv"
      }
    ],
    "texkeys": [
      "Gong:2012thh",
      "Li:2012zs"
    ],
    "citeable": true,
    "keywords": [
      {
        "value": "Cryogenics",
        "source": "author"
      },
      {
        "value": "Xenon",
        "source": "author"
      },
      {
        "value": "Dark Matter",
        "source": "author"
      },
      {
        "value": "xenon: liquid",
        "schema": "INSPIRE"
      },
      {
        "value": "dark matter",
        "schema": "INSPIRE"
      },
      {
        "value": "efficiency",
        "schema": "INSPIRE"
      },
      {
        "value": "cryogenics",
        "schema": "INSPIRE"
      },
      {
        "value": "scintillation counter",
        "schema": "INSPIRE"
      },
      {
        "value": "heat engineering",
        "schema": "INSPIRE"
      },
      {
        "value": "gas: flow",
        "schema": "INSPIRE"
      },
      {
        "value": "deep underground detector",
        "schema": "INSPIRE"
      },
      {
        "value": "pressure: time dependence",
        "schema": "INSPIRE"
      }
    ],
    "refereed": true,
    "abstracts": [
      {
        "value": "Panda-X is a liquid xenon dual-phase detector for the Dark Matter Search. The first modestly-sized module will soon be installed in the China JinPing Deep Underground Laboratory in Sichuan province, P.R. China. The cryogenics system is designed to handle much larger detectors, even the final version in the ton scale. Special attention has been paid to the reliability, serviceability, and adaptability to the requirements of a growing experiment. The system is cooled by a single Iwatani PC150 Pulse Tube Refrigerator. After subtracting all thermal losses, the remaining cooling power is still 82W. The fill speed was 9 SLPM, but could be boosted by LN2 assisted cooling to 40 SLPM. For the continuous recirculation and purification through a hot getter, a heat exchanger was employed to reduce the required cooling power. The recirculation speed is limited to 35 SLPM by the gas pump. At this speed, recirculation only adds 18.5 W to the heat load of the system, corresponding to a 95.2 % efficiency of the heat exchanger.",
        "source": "arXiv"
      }
    ],
    "references": [
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/786214"
        },
        "reference": {
          "misc": [
            "(XENON10 collaboration) :"
          ],
          "label": "1",
          "title": {
            "title": "Limits on spin-dependent WIMP-nucleon cross sections from the XENON10 experiment"
          },
          "authors": [
            {
              "full_name": "Angle, J."
            }
          ],
          "publication_info": {
            "year": 2008,
            "artid": "091301",
            "journal_title": "Phys.Rev.Lett.",
            "journal_volume": "101"
          }
        },
        "curated_relation": false
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/896231"
        },
        "reference": {
          "misc": [
            "(XENON100 collaboration)"
          ],
          "label": "2",
          "title": {
            "title": "Dark Matter Results from 100 Live Days of XENON100 Data"
          },
          "authors": [
            {
              "full_name": "Aprile, E."
            }
          ],
          "publication_info": {
            "year": 2011,
            "artid": "131302",
            "journal_title": "Phys.Rev.Lett.",
            "journal_volume": "107"
          }
        },
        "curated_relation": false
      },
      {
        "reference": {
          "misc": [
            "The Panda-X experiment CDR, to be published in 2012"
          ],
          "label": "3"
        }
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/918021"
        },
        "reference": {
          "misc": [
            "(XENON100 collaboration)"
          ],
          "label": "4",
          "title": {
            "title": "The XENON100 Dark Matter Experiment"
          },
          "authors": [
            {
              "full_name": "Aprile, E."
            }
          ],
          "publication_info": {
            "year": 2012,
            "artid": "573",
            "page_start": "573",
            "journal_title": "Astropart.Phys.",
            "journal_volume": "35"
          }
        },
        "curated_relation": false
      },
      {
        "reference": {
          "misc": [
            "Iwatani Industrial Gases Corp, Model PC150 Pulse Tube Refrigerator"
          ],
          "label": "5"
        }
      },
      {
        "reference": {
          "misc": [
            "Cryocoolers 13, Part 15, 689-694,(2005) Science+Business Media, Inc., New York"
          ],
          "label": "6",
          "title": {
            "title": "High Power Pulse Tube Cryocooler for Liquid Xenon Particle Detectors"
          },
          "authors": [
            {
              "full_name": "Haruyama, T."
            },
            {
              "full_name": "Kasami, K."
            },
            {
              "full_name": "Matsubara, Y."
            },
            {
              "full_name": "Nishitani, T."
            },
            {
              "full_name": "Giboni, K."
            },
            {
              "full_name": "Aprile, E."
            }
          ],
          "imprint": {
            "publisher": "Springer"
          }
        }
      },
      {
        "reference": {
          "misc": [
            "Oxford Instruments, Helium Compressor M600A"
          ],
          "label": "7"
        }
      },
      {
        "record": {
          "$ref": "https://inspirehep.net/api/literature/842987"
        },
        "reference": {
          "misc": [
            "(XENON10 collaboration)"
          ],
          "label": "8",
          "title": {
            "title": "Design and performance of the XENON10 dark matter experiment"
          },
          "authors": [
            {
              "full_name": "Aprile, E."
            }
          ],
          "publication_info": {
            "year": 2011,
            "artid": "679",
            "page_start": "679",
            "journal_title": "Astropart.Phys.",
            "journal_volume": "34"
          }
        },
        "curated_relation": false
      },
      {
        "reference": {
          "misc": [
            "Lakeshore Cryotronics, Cryogenic Temperature Controller Model 340"
          ],
          "label": "9"
        }
      },
      {
        "reference": {
          "label": "10",
          "authors": [
            {
              "full_name": "Giboni, K.L."
            },
            {
              "full_name": "Aprile, E."
            },
            {
              "full_name": "Choi, B."
            },
            {
              "full_name": "Haruyama, T."
            },
            {
              "full_name": "Lang, R.F."
            },
            {
              "full_name": "Lim, K.E."
            },
            {
              "full_name": "Melgarejo, A.J."
            },
            {
              "full_name": "Plante, G."
            }
          ]
        }
      },
      {
        "reference": {
          "misc": [
            "6, 3002, (2011)"
          ],
          "label": "10",
          "title": {
            "title": "Xenon Recirculation-Purification with a Heat Exchanger"
          },
          "authors": [
            {
              "full_name": "J. of Instr"
            }
          ]
        }
      },
      {
        "reference": {
          "misc": [
            "Kaori Technology Co., Ltd., Model K070x70"
          ],
          "label": "11"
        }
      },
      {
        "reference": {
          "misc": [
            "KNF pump, Model N143AN.12E"
          ],
          "label": "12"
        }
      },
      {
        "reference": {
          "misc": [
            "SAES Pure Gas, Purifier Model PS15-MT50"
          ],
          "label": "13"
        }
      }
    ],
    "public_notes": [
      {
        "value": "10 pages, 5 figures",
        "source": "arXiv"
      }
    ],
    "arxiv_eprints": [
      {
        "value": "1207.5100",
        "categories": [
          "astro-ph.IM"
        ]
      }
    ],
    "document_type": [
      "article"
    ],
    "preprint_date": "2012-07",
    "control_number": 1123430,
    "legacy_version": "20170221104811.0",
    "number_of_pages": 10,
    "inspire_categories": [
      {
        "term": "Astrophysics"
      },
      {
        "term": "Experiment-HEP"
      },
      {
        "term": "Instrumentation"
      }
    ],
    "legacy_creation_date": "2012-07-23",
    "external_system_identifiers": [
      {
        "value": "2013JInst...8P1002G",
        "schema": "ADS"
      },
      {
        "value": "SPIRES-9670971",
        "schema": "SPIRES"
      }
    ]
  },
  "updated": "2023-03-06T23:08:48.248746+00:00"
}